Overview

Quick Details

Place of Origin:

Zhejiang, China

Brand Name:

EPT

Model Number:

VOL- IEC112S2250-6P

Usage:

Boat, Car, Electric Bicycle, Fan, Home Appliance, Shell Eco-marathon Competition Car

Certification:

CCC, CE, ROHS, UL

Type:

brushless DC motor

Torque:

21.48Nm

Construction:

Permanent Magnet

Commutation:

Brushless

Protect Feature:

Waterproof

Speed(RPM):

1000rpm

Continuous Current(A):

6.42A

Efficiency:

IE 4

Housing:

Aluminum Frame

Speed Range:

1000rpm

Material:

Permanent Magnets

Controller:

Customized, Optional

Braker:

Optional

Insulation Class:

Class F

Enclosure:

IP54

Poles:

6P

Wire:

100% copper

Duty:

S1 (continuous)

Supply Ability

Supply Ability:
10000 Unit/Units per Month

Packaging & Delivery

Packaging Details
low noise 6 Poles 3HP 1000rpm IEC Brushless dc motor Packing: Standard sea or air package will be perfectly protected in the delivery.
Port
FOB Ningbo

Online Customization

Product Display

Motor type Output Power Voltage Load Speed Rated Torque Efficiency Noise IP Class
KW V A RPM Nm % dB
VOL- IEC90S2250-2P 2.25 220 ac 6.42 3000 7.16 92 62 IP 54
VOL- IEC100S2250-4P 2.25 220 ac 6.42 1500 14.33 92 62 IP 54
VOL- IEC112S2250-6P 2.25 220 ac 6.42 1000 21.48 92 62 IP 54
VOL- IEC112S3750-2P 3.75 220 ac 10.70 3000 11.94 92.5 62 IP 54
VOL- IEC112S3750-4P 3.75 220 ac 10.70 1500 23.88 92.5 62 IP 54

VIEW MORE PLS CONTACT US >>>

Other Products

Process Flow

About Us

Packing&Transport

Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.

What to do: Replace the fuse or reset the breaker.

Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.

Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.

Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.

Q:On initial installation, motor fails to start up,what to do?
A:Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.

Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.

Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.

Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.

Likely cause: Brushes are worn.
What to do: Verify brush length.

Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.

Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.

Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.